如果您對(duì)該產(chǎn)品感興趣的話,可以
產(chǎn)品名稱:
SK-L200TH IIα
產(chǎn)品型號(hào):
SATO溫濕度計(jì)
產(chǎn)品展商:
其它品牌
簡(jiǎn)單介紹
SK-L200TH IIα,NSII-HQ,NSII-Q,NSII-S,NSII-TQ,PALMA II,PC-6800,SK-010,SK-020,SK-100THP,SK-1100,SK-1120,SK-120CHB,SK-1250MC,SK-250WPII-K,SK-250WPII-N,SK-250WPII-R,SK-250WPII-T
|
SK-L200TH IIα的詳細(xì)介紹 |
SK-L200TH IIα Features - Memory capacity is 8100 lines of data perchannel.
(It is possible to store the data for about 506 days with loginterval of 90 minutes and about 168 days with log interval of 30minutes.) - The method of storing data can be selectableamong four logging options :
- Once (default)
When Once is chosen, the datalogger keeps logging until the memorybecomes full. The datalogger stops logging when 8100 lines of dataare recorded. - Repeatability (overwriting)
The datalogger overwrites the exsisting data from the start oncethe 8100 lines of data are recorded. This is ideal for collectingdata during a certain period. - Ends at (limited amount)
With this logging option, you can specify the end-point for thedatalogger to stop logging. This setting is ideal when you want tolimit the amount of data to be collected. - By page (partitioning)
The storage memory is partitioned into blocks, each having thecapacity to store 200 lines of data. This enables the datalogger toperform four different tasks in sequence while storing each task?sdata in one of the four different memory blocks (pages). This isideal when you want to collect data from multiple sites using onedatalogger.
- The software for data analysis and realtimetransmission is attached as standard accessories.
- The date and time to start logging automaticallycan be specified by setting the preset start.
- The measurement data can be transmitted inrealtime to a personal computer.
- USB transmission is adopted .
- The upper and lower thresholds for warning canbe set. When the temperature or humidity threshold is triggered,the alarm mark (Hi or Lo) will light.
- Probes are interchangeably used with mainunits.
- The storage memory can be varified with thememory indicator.
- The log interval can be selected from 14options: 1 sec, 2 sec, 5 sec, 10 sec, 15 sec, 30 sec, 1 min, 2 min,5 min, 10 min, 15 min, 30 min, 60 min. and 90 min.
- When the power is turned off, data stored in theEEPROM memory is retained.
- The datalogger ID can be set. This is useful toidentify multiple dataloggers.
- By using data analysis software attached,acquired data can be evaluated easily and quickly, and alsoevaluated by using commercial spreadsheet software supporting the"CSV"extertion such as Lotus 1-2-3 and MicrosoftExcel.
|
By Data Analysis Software | By Real-Time Transmission Software |
- By using software attached, logged data can beeasily displayed as graphs on a PC.
- The data transmitted from up to 4 dataloggers (8channels max.) can be analyzed being displayed in a graph.
- Downloaded data with the"CSV"extertion can beevaluated by using Lotus 1-2-3, Microsoft Excel and othercommercial spreadsheets.
- The highest value, the lowest value and averagevalue per channel can be automatically calculated.
- The Scroll-bar function can zoom in on anyregion of the graphs that you want to.
- Minimum system requirements
OS: Windows2000 (upper version of SP 4),WindowsXP Memory: more than 256MB CPU: Pentium III 700MHz or better Free disk space: more than 150MB Provide USB ports.
|
|
|